Precisely planned and controlled airflow control is a central pillar for occupational safety, process stability, and quality in concrete demolition, interior demolition, tunnel construction, and special demolition. It protects against fine dust, removes aerosols and exhaust gases, cools the power unit, and creates manageable working conditions—even in confined, enclosed, or deep areas. In combination with hydraulic tools such as hydraulic demolition shear as well as hydraulic wedge splitter, the guidance of supply air and exhaust air often determines whether a project proceeds with low disruption, cleanliness, and in compliance with standards.
Definition: What is meant by airflow control
Airflow control refers to the planned directing of airflow in work areas: the provision of supply air, capture at emission sources, removal of contaminated air, and controlled discharge outdoors or through suitable filtration. It encompasses air change rates, flow paths, pressure zones (negative and positive pressure), the cross-sections of hoses and ducts, as well as the selection and positioning of fans and filters. In practice, airflow control links technical aspects of ventilation with dust-reduction measures (e.g., source capture and water mist) and the thermal management of hydraulic power packs. Especially in concrete demolition, in the processing of natural stone, or in tunnel heading, it serves to protect against quartz-containing fine dust, remove exhaust gases, and cool components.
Planning and sizing of airflow control on construction sites and in existing buildings
Design begins with the question: What substances are generated, where do they occur, and what air quality is required at the workplace? From this, volume flows, inlet and outlet points, pressure concepts, and routing are derived. The goal is a directed flow of clean supply air toward the emission source—and from there captured by extraction—without backflow into occupied areas.
Air change rate and volume flow
In enclosed spaces, air change rates are often used, supplemented by specific volume flow at emission sources. For operations with the hydraulic demolition shear or for dry work, the combination of increased general ventilation and source capture is sensible. For point sources, a short path between the source and the suction opening is critical; the closer the capture, the lower the total air quantity required.
Pressure zones and flow paths
Negative-pressure areas prevent contaminated air from escaping into clean zones. Exhaust openings are placed strategically so that a directed airflow is created—from the supply air side through the work area to the exhaust. Doors, airlocks, and temporary partitions support flow guidance. In shafts and tunnels, fresh air must safely reach the work area; exhaust air must be routed so that it does not return into the supply air.
Ducts, hoses, and losses
Long, narrow, or kinked hoses increase pressure losses and reduce the effective volume flow. Smooth interior surfaces, large radii, and the shortest possible paths improve performance. Branches should be designed to avoid dead zones. If needed, axial and radial fans can be combined—axial for high volume flows over longer distances, radial for higher pressure requirements at the source.
Filtration and dust reduction
Airflow control is complemented by dust reduction: Water mist directly at the work point reduces dust release, while filter stages lower residual loads. The correct sequence is crucial: first bind at the source, then capture and filter. Recirculation of air back into workspaces requires filtration matched to the exposure; for critical dusts, pure exhaust routing to the outside is generally preferable.
Measurement and documentation
Flow direction (e.g., smoke test), volume flow, and pressure differentials are regularly checked and documented. Temporary changes—such as relocating a hydraulic wedge splitter or creating new openings—necessitate continuous adaptation of the ventilation concept.
Airflow control in concrete demolition and special demolition
Crushing, shearing, and cutting concrete generate fine dust that must be captured in a targeted manner. The hydraulic demolition shear generates dust and fragments primarily in the jaw area; the most efficient measure is source capture combined with water wetting of the material. Supply air is introduced from the clean area, while exhaust air is removed immediately downstream of the emission zone and filtered or discharged outdoors.
Local capture instead of general room ventilation alone
General room ventilation often merely stirs up dust; precise, point-of-use capture reduces total air volume and increases effectiveness. For mobile operations, flexible suction hoses with stable guidance that follow tool movement are recommended.
Low-vibration methods and airflow control
Hydraulic wedge splitters operate without impact and thus reduce secondary emissions such as fine suspended dust. Nevertheless, controlled airflow control remains important to reliably remove dislodged particles and any aerosols—especially indoors or in shafts.
Interior demolition and cutting: ventilation in existing buildings
During interior demolition, multiple emission sources often coincide: cutting operations, localized chiseling, material transport, and interim storage. The ventilation concept relies on clearly separated zones: supply air in escape routes and service corridors, negative pressure in the work area, and exhaust routed via the shortest path outdoors. Mobile filter units can improve exhaust air quality but do not replace capture at the source.
Openings and flow path
Windows, core drilling openings, or temporary penetrations serve as defined supply and exhaust points. The position of extraction openings is chosen so that the airflow is guided past the operator to the emission source and subsequently to the exhaust.
Rock excavation and tunnel construction: ventilation and gas management
In tunnel and drift construction, fresh air supply, removal of exhaust gases, and control of dust and gas concentrations are central. Axial fans with long ventilation hoses bring supply air up to the tunnel face; contaminated air is routed back via separate lines. As directions change, branches are added, and advance progresses, hose routing must be continuously adjusted to keep flow direction unambiguous.
Source, distance, capture
Hydraulic tools generate low direct emissions; however, dust forms during material processing. A combination of supply air to the front, source capture, and consistent exhaust routing prevents backflow into occupied areas.
Hydraulic power packs: cooling, supply air, and exhaust routing
Hydraulic power units require sufficient supply air to cool the engine, hydraulic oil, and power electronics. Waste heat and any exhaust gases must be removed in a way that avoids recirculation loops. Keep intake and discharge directions clear; keep filters and screens clean to prevent pressure losses. Indoors, separating the equipment zone (fresh air supply) from the work zone (targeted exhaust) is expedient.
Setup and noise
Placement is arranged to reduce noise immissions and to ensure flow noise is not amplified into work zones. Gentle bends, adequately sized cross-sections, and short runs reduce flow velocity and thus noise generation.
Special operations: tank cutting and work in enclosed vessels
For work on vessels, shafts, or enclosed spaces, airflow control additionally aims to avoid potentially hazardous atmospheres. As a rule: remove contaminated air in a targeted manner, supply fresh air safely, and prevent backflow. Conditions must be carefully checked before starting; implementation follows suitable hazard analysis and general technical rules. If in doubt, suspend work until safe conditions are established.
Health protection: dust, aerosols, and exhaust gases
Quartz fine dust from concrete, mortar, and natural stone, metal dust when cutting reinforcement, and exhaust gases require risk-adjusted airflow control. In addition to source capture, water application, adapted volume flows, and clearly defined pressure zones significantly reduce exposure. Personal protective measures complement technical precautions; they do not replace airflow control.
Practical tips for effective airflow control
- Prioritize capture at the source—especially for work with hydraulic demolition shear and dry scoring.
- Keep supply air paths clear; route exhaust paths short, straight, and with large radii.
- Size hoses and ducts adequately; avoid kinks and unnecessary branches.
- Maintain negative pressure in the work area so contaminated air does not escape into clean zones.
- Use a combination of water mist and extraction to bind dust at the moment of generation.
- Continuously check ventilation: visual tests of flow direction, verification of volume flows, and filter condition checks.
- Adapt ventilation to construction progress—especially when openings change, wall breakthroughs are created, or equipment is relocated.
Typical mistakes and how to avoid them
- Only room ventilation without source capture: Better is point-of-use extraction directly at the work point.
- Unclear flow paths: Position supply and exhaust openings so the direction is unambiguous.
- Undersized cross-sections: Adequate sizing prevents high pressure losses and ineffective capture.
- Recirculation loops at power units: Separate intake areas from discharge zones to preserve cooling and air quality.
- Lack of adjustment: Regularly align ventilation with site changes, for example after relocating hydraulic wedge splitter.
Interaction of work methods and airflow control
The choice of work method influences the requirements: methods with lower impact energy and reduced dust generation make airflow control easier but do not replace it. In practice, a consistent combination of low-emission processing steps, water application, precise source capture, and a logically structured supply/exhaust architecture has proven effective. This keeps work areas in concrete demolition, interior demolition, rock excavation, and tunnel construction controlled and safe—even under changing site conditions and with mobile hydraulic tools from Darda GmbH.