Breakthrough stabilization

Breakthrough stabilization is a central topic in concrete demolition, interior demolition, and the controlled creation of openings. It refers to the overall technical and organizational concept used to prevent uncontrolled breakthroughs of material, fall hazards, and structural instabilities. In practice, this concerns the safe creation of wall and ceiling openings, the removal of component edges, and the controlled separation of reinforced concrete. Tools such as concrete pulverizers and stone and concrete splitters enable finely metered force application and guided crack propagation— a core aspect of any effective breakthrough stabilization.

Definition: What is meant by breakthrough stabilization

Breakthrough stabilization refers to the entirety of all structural, technical, and organizational measures that, during the creation or enlargement of openings in concrete, masonry, or rock, prevent unintended breakthroughs, tilting of components, and the fall of people and materials. This includes temporary shoring and catching, a targeted sequence of cuts and splits, controlled edge removal, edge protection, and the safe cutting of reinforcement. When working with force-based methods—such as with stone and concrete splitters or concrete pulverizers—the focus is on controlled crack initiation and guidance to preserve the load-bearing behavior of adjacent components and to make load redistribution predictable.

Planning fundamentals and assessment of load-bearing behavior

Effective breakthrough stabilization begins with an assessment of the existing structure: structural data, material properties, reinforcement layout, and any prestressing are decisive. Openings alter load paths; local failure mechanisms (e.g., punching cones in slabs, edge spalling, overturning moments in walls) can occur. A prior structural assessment and—where necessary—temporary shoring or propping are therefore fundamental steps. In execution, it has proven effective to remove components in small, controlled sections. With concrete pulverizers, edge regions can be removed piece by piece, while stone and concrete splitters initiate cracks along a defined drilling pattern. The resulting low vibration helps avoid weakening adjacent components and prevents unwanted breakthroughs. hydraulic power units supply these tools with the required pressure, and adjusting the pressure level to material thickness and reinforcement is essential for crack control.

Typical application areas and scenarios

The requirements for breakthrough stabilization vary depending on the task and environment. The following scenarios illustrate typical focal points:

Concrete demolition and special demolition

When deconstructing reinforced concrete components, guiding the fracture is the focus. Edges are often removed with concrete pulverizers to keep piece weights small. For massive cross-sections, stone and concrete splitters steer crack propagation from borehole to borehole to prevent uncontrolled spalling. Reinforcing steel is then selectively cut with steel shears or multi cutters.

Interior demolition and cutting

In interior demolition, breakthrough stabilization is especially important in occupied or sensitive buildings: load redistribution due to openings should be minimized, and vibration and noise should be limited. A sequence of pre-drilling, sawing, and targeted removal with pulverizers reduces risks. Reinforcement is cut in a controlled manner to avoid a sudden release of tensile forces.

Rock excavation and tunnel construction

In rock, the goal is to control unintended cavity breakthroughs and loose rock—key considerations in rock demolition and tunnel construction. Rock splitter cylinders introduce forces in a defined way and reduce brittle failures. At tunnel interfaces, the tunnel face, support, and removal are closely coordinated to ensure the stability of the excavation edge.

Natural stone extraction

When freeing natural stone blocks, fine splitting techniques enable clean separation along existing joints. Controlled crack guidance prevents unusable fractures and protects adjacent bench faces.

Special operations

For special tasks—such as in areas with explosive atmospheres or when cutting vessels—the avoidance of uncontrolled penetrations is paramount. Cold-cutting methods and a carefully planned sequence of cuts and splits provide maximum control over material behavior and minimize secondary hazards.

Technical measures of breakthrough stabilization

The combination of structural safeguards and an appropriate separation strategy forms the core of breakthrough stabilization. Key building blocks include:

  • Shoring and propping: Temporary supports, support scaffolds, and brackets reduce risks of overturning and punching before the first cut is made.
  • Defined sequence of cuts and splits: Pre-drilling, kerf cuts, and dividing into partial segments limit stresses and avoid uncontrolled breakage.
  • Guided crack propagation: Stone and concrete splitters initiate cracks along a drill pattern; pressure is increased step by step to observe and adjust crack progression.
  • Edge removal with concrete pulverizers: Nibbling edges in small sections keeps piece weights low and protects concrete edges from spalling.
  • Rebar cutting: After concrete removal, reinforcement is cut in a controlled manner with steel shears, multi cutters, or combination shears to relieve residual tensile forces.
  • Fixed points and lifting gear: Load securing with suitable anchorage points prevents components from dropping through during the final cut.
  • Vibration and noise control: Splitting techniques and pulverizer work reduce vibration—an advantage in sensitive environments.

Procedure in practice: step by step

  1. Survey of existing conditions: Review drawings, material condition, reinforcement layout, prestressing, existing damage, and load paths.
  2. Temporary safeguarding: Shore/prop according to the structural assessment; establish edge and fall protection.
  3. Define drill pattern and cut path: Choose borehole spacing, kerf cuts, and segment sizes to predetermine crack paths.
  4. Preparatory separation cuts: Saw cuts for defined edges; plan water management and retention.
  5. Controlled splitting: With stone and concrete splitters, increase pressure stepwise, observe crack formation, and supplement the drill pattern if needed.
  6. Edge removal: Use concrete pulverizers to release edges in small sections, keep piece weights low, and secure drop zones.
  7. Cut reinforcement: Selectively cut remaining reinforcement with shears; reduce tensile forces in a controlled manner.
  8. Removal without load transfer: Secure and remove freed segments with lifting equipment; protect the opening after breakthrough.
  9. Inspection and follow-up safeguarding: Check component edges, rework damaged areas, and continue temporary safeguards as adjusted.

Special aspects for ceiling and wall openings

For ceiling openings, punching and fall risks dominate. Early edge shoring and segmenting into small component pieces are crucial. For walls, pay attention to overturning moments and shear weakening; working top-down with concrete pulverizers minimizes uncontrolled breakage. For openings in load-bearing walls, temporary lintels or catch beams must be installed before cutting the concrete. Prestressing requires an especially cautious sequence of cuts and splits.

Material and component dependencies

Reinforced concrete: The high tensile strength of reinforcement requires a clear separation strategy; splitters guide cracks, and pulverizers reduce edge loads.
Masonry: Brittle behavior with unguided fracture surfaces requires low force levels and a tight drill pattern.
Prestressed concrete/fiber-reinforced concrete: Additional prestressing or fiber action can deflect crack paths; increase pressure levels slowly and expose reinforcement early.
Rock/natural stone: Utilize joints and bedding planes; use rock splitter cylinders with moderate stroke pressures to avoid unintended breakouts.

Occupational safety, environment, and neighborhood

Safety measures include securing fall edges, establishing protected areas, using appropriate personal protective equipment, and controlling dust, water, and noise. Low-vibration methods—especially splitting and pulverizer work—help protect adjacent structures. The applicable codes, accident prevention regulations, and operational permits must always be observed; legal requirements can vary by project and region.

Quality control and documentation

Clear documentation of safeguarding concepts, test reports for shoring, measurement logs (e.g., deformation, vibration), and photographic records of the sequence of cuts and splits improve execution safety. Deviations from the plan—such as changed reinforcement layouts—must be identified early and incorporated into breakthrough stabilization.

Common failure patterns and how to avoid them

  • Insufficient shoring: Dimension and check catching measures before separation work.
  • Incorrect segmentation: Oversized piece weights increase breakthrough risk; choose smaller sections.
  • Unplanned fracture paths: Without a drill pattern or kerf cut, uncontrolled cracks develop; predetermine crack guidance.
  • Sudden reinforcement cutting: Reduce tensile forces gradually; perform shear cuts in a controlled manner.
  • Excessive force levels: During splitting, increase pressure slowly and observe material response.
  • Unclear edge protection: Secure drop zones, define anchorage points, and do not move loads over people.