The armored slab is considered a particularly resilient, heavily reinforced reinforced concrete slab designed for extreme loads, protective functions, and penetration resistance. Such slabs are found in protective structures, safety-critical industrial facilities, or military structures. In deconstruction, they pose special demands due to large thicknesses, high reinforcement ratios, and often integrated steel facings. For selective demolition, cutting, and splitting, depending on configuration and boundary conditions, concrete pulverizers, rock and concrete splitters, and additionally steel shears, multi cutters, combination shears, and tank cutters are used. This article explains fundamentals, typical constructions, and proven practical approaches from the investigation concept through to controlled deconstruction.
Definition: What is meant by armored slab
An armored slab is a above-average thick, heavily reinforced reinforced concrete slab that often contains additional steel armor (e.g., plates, lamellae, beams). The objective is very high load-bearing capacity, resistance to perforation, and robustness against mechanical impacts. Typical features include concrete compressive strength classes from C30/37 upward, multiple reinforcement layers with small bar spacing, punching shear and shear reinforcement, as well as design details such as composite anchors or cast-on strengthening zones. In historic protective structures and bunkers, thicknesses well over 1.0 m are found; in industrial applications, composite slabs with embedded steel plates are also common.
Build-up, materials, and design details
Armored slabs differ from conventional reinforced concrete slabs in their layered build-up, material quality, and high reinforcement ratio. A composite of concrete and steel armor is often present, sometimes with prestressed elements to limit cracking and deflection.
Concrete matrix and strength
Dense, high-strength concretes with low water absorption and high abrasion resistance are used. Additives and low w/c ratios increase compressive strength and toughness. Topping concrete, grouts, or repair mortars can selectively strengthen zones.
Reinforcement and composite elements
Multi-layer mesh and bar reinforcement with reduced spacing, additional shear and punching shear reinforcement, and composite anchors are typical. For armor layers, steel plates, T-beams, or lamellae are integrated to ensure composite action, which strongly influences internal force distribution and demolition behavior.
Steel armor and embedded components
Steel facings made of high-strength plates, welded lamellae, or beam grids increase penetration resistance. Embedded components (conduits, brackets, loops, guide rails) hinder milling and sawing and can promote sparking, edge cracking, or tool wear.
Typical applications and functions
Armored slabs are encountered by specialists in protective and special construction, in safety-critical industrial zones, technical centers, or historic facilities. Their functions include carrying large point loads, protection against perforation and fragments, fire and explosion resistance, and shielding of sensitive areas. In deconstruction, this manifests as high material toughness, a strong steel content, and complex composite effects.
Challenges in the deconstruction of armored slabs
The combination of great thickness, dense reinforcement, and steel armor leads to increased tool wear, slower progress, and high safety requirements. In addition, vibrations, noise, and dust emissions often must be strictly limited. From a structural standpoint, load redistribution, temporary shoring, and controlled demolition segments must be planned to avoid unintended failure mechanisms.
Investigation and documentation
Before starting, building documents should be evaluated, and non-destructive testing methods such as radar, ferroscan, and ultrasound are advisable. Core drilling verifies layered build-up, reinforcement layers, and slab thicknesses. The results feed into a detailed segmentation and securing concept.
Structural considerations and securing
Demolition phases require forward-looking load path management. Temporary shoring, edge beams, and compression posts secure openings until segments are removed. Separation cuts define controlled demolition zones.
Emission control
Dust and noise reduction through water misters, localized enclosures, and low-vibration methods is central in sensitive areas. The choice of method is guided by requirements, neighborhood conditions, and subsoil sensitivity.
Methods and tools for selective demolition
Various hydraulic methods can be used to process an armored slab and can be combined depending on the build-up:
- Concrete pulverizers: mechanical breaking of concrete, targeted exposure of reinforcement, controlled removal of edges and topping concrete.
- Stone and concrete splitters or stone splitting cylinders: low-noise, low-vibration widening of pre-drilled grids to open thick concrete sections without impact energy.
- Combination shears: switching between concrete breaking and cutting enables flexible work in composite zones.
- Steel shears and multi cutters: cutting reinforcement, lamellae, and structural steel after exposure.
- Tank cutters: cutting particularly thick steel plates or armor steel sections, for example in reinforced top layers.
- Hydraulic power packs: power supply and control for the tools, matched to pressure and flow requirements.
Low-noise demolition with stone and concrete splitters
In areas with strict immission requirements, splitters are a gentle alternative to impact tools. After setting a drill-hole grid, splitter cylinders are inserted and the section is widened in a controlled manner. This creates cracks along the intended separation lines, which can then be broken out with concrete pulverizers.
Selective breaking with concrete pulverizers
Concrete pulverizers break the concrete material in a targeted way and allow the step-by-step exposure of reinforcement. Edges can be removed, topping concrete lifted off, and openings created without activating the entire component. This reduces uncontrolled crack propagation.
Cutting the reinforcement and steel armor
After exposing the steel, steel shears or multi cutters take over cutting reinforcement and structural steel. For massive steel facings, tank cutters are suitable. Combination shears enable efficient switches between breaking and cutting, which reduces cycle time in composite slabs.
Work steps in deconstructing an armored slab
- Assessment of existing conditions: review drawings, site visits, probing and tests (radar, core drilling).
- Shoring and safeguarding concept: define temporary structural members, fall protection, and protected zones.
- Preparation: establish work access, utilities, position hydraulic power packs, and set up dust and water protection measures.
- Separation cuts and grids: set up sawing technology or drill-hole grids; align segment sizes with lifting gear and logistics.
- Open the concrete: depending on the facing, open the slab along the separation lines with stone and concrete splitters or concrete pulverizers.
- Expose and cut reinforcement: reveal the steel and cut with steel shears or multi cutters; use tank cutters for thick plates.
- Segment removal: place lifted segments, advance intermediate shoring, secure edges.
- Finishing work: remove residual reinforcement, trim edges, and produce a planar surface.
- Source-separated sorting: record concrete and steel separately and prepare for recycling streams.
Safety, environment, and legal aspects
Work on armored slabs is subject to high requirements for occupational safety, emission control, and disposal. Hazards from falls, crushing, cutting and pinch points, as well as sparking, must be minimized through training, barriers, and personal protective equipment. Dust and noise emissions are limited through appropriate methods, water spraying, and orderly cut sequences. Requirements from authority permits, building codes, and technical rules must be carefully observed; binding case-by-case assessments are carried out by the responsible specialists on site.
Practical scenarios
In historic protective structures with 1.5 m thick slabs and steel facing, the opening often proceeds in two stages: first, rows of drill holes are set and opened with splitter cylinders; subsequently, a concrete pulverizer breaks out the loosened areas. The exposed steel plate is segmented and cut with a tank cutter or steel shear.
In industrial facilities with locally reinforced machine foundations, the topping concrete is removed in sections with concrete pulverizers. Reinforcement bundles can then be cut with multi cutters without affecting adjacent areas.
Distinction from other slab types
Compared to conventional reinforced concrete slabs, the armored slab exhibits significantly higher toughness and reinforcement density and often a composite armor. In contrast to massive concrete blocks (without a high steel content), its deconstruction is shaped less by pure volume and more by the combination of concrete and steel. This affects tool selection, cut sequence, and the removal concept.
Relevance to products and application areas of Darda GmbH
Armored slabs are closely related to the application areas of concrete demolition and special deconstruction, strip-out and cutting, as well as special operations. Concrete pulverizers are suitable for controlled breaking of the concrete matrix and exposing the reinforcement. Where vibrations must be minimized, stone and concrete splitters and stone splitting cylinders deliver precise, low-noise openings. For the subsequent cutting of exposed steels, steel shears, multi cutters, and, for massive steel facings, tank cutters are appropriate. Combination shears combine breaking and cutting in one sequence. The hydraulic power packs provide the required performance and are matched to the respective method.