{"id":19528,"date":"2025-11-20T08:17:33","date_gmt":"2025-11-20T07:17:33","guid":{"rendered":"https:\/\/www.darda.de\/?page_id=19528"},"modified":"2026-05-04T11:38:03","modified_gmt":"2026-05-04T09:38:03","slug":"paver-bedding-layer","status":"publish","type":"page","link":"https:\/\/www.darda.de\/en\/knowledge\/paver-bedding-layer","title":{"rendered":"Paver bedding layer"},"content":{"rendered":"<div class=\"wissen-inhaltsbereich\">\n<p>The paver bedding layer is the laying course located directly beneath the paving stones or slabs. It largely determines the flatness, load-bearing capacity, and durability of a paved surface-from garden driveways to heavily trafficked areas. In new construction, repair, and deconstruction, the choice of bedding material, the correct layer thickness, and careful execution play a central role. In selective demolition and remodeling work, for example on curb stones, concrete slabs, or edge restraints, methods with <em>low vibration levels<\/em> are often used. This creates points of contact with handheld, hydraulic tools such as <strong>hydraulic wedge splitter<\/strong> or <strong>concrete demolition shear<\/strong>, as used in <strong>concrete demolition<\/strong> and <strong>special demolition<\/strong>. The long-term performance of the pavement arises from the interaction of <em>subgrade, base course, bedding, stone, and jointing<\/em>; each layer must be compatible with the others.<\/p>\n<h2>Definition: What is meant by the paver bedding layer?<\/h2>\n<p>The paver bedding layer (also bedding or laying course) is the screeded, typically 3-5 cm thick layer of sand, chippings, or mortar that lies between the base course and the paving stones or slabs to be installed. It serves to level out final irregularities in the base course, to transfer loads uniformly into the sublayer, and-in unbound designs-to drain water. Depending on the loading, the stone material, and the desired joint performance, the bedding is executed unbound (sand\/chippings) or bound (drainage or grouting mortar). For durable performance, <strong>grain size distribution<\/strong>, <strong>moisture condition<\/strong>, and <strong>even support<\/strong> are decisive.<\/p>\n<h2>Build-up, materials, and functions of the bedding layer<\/h2>\n<p>A functioning bedding layer ensures the exact elevation, a homogeneous bearing surface, and the long-term joint performance of the pavement. In unbound execution, angular chippings with a low fines content are typically used to maintain drainage capacity. In bound execution, cement-bound, often water-draining mortars are used. Decisive factors include suitable grading, the correct installation thickness, and a uniform strike-off so that the stones or slabs are supported over their area after vibrating in or tapping in, without grain rearrangement leading to settlement. Contamination with clay, silt, or cement paste must be avoided, and segregation of the aggregate during transport and placement should be minimized.<\/p>\n<h2>Requirements for aggregate composition, layer thickness, and flatness<\/h2>\n<h3>Grain shape and grading curve<\/h3>\n<p>For unbound bedding, angular, crushed aggregates have proven effective because they interlock and still allow water to pass. Common options include:<\/p>\n<ul>\n<li>Chippings 1\/3, 2\/5, or 2\/8 for pavers and small-format slabs<\/li>\n<li>Chippings 4\/8 for large-format slabs in permeable constructions<\/li>\n<li>Sand 0\/2 or 0\/4 for lower loads or traditional construction<\/li>\n<\/ul>\n<p>A <em>low fines content<\/em> reduces the risk of clogging and frost heave. Sand that is too fine can cause water to accumulate and make the bedding \u201cpump.\u201d Where recycled aggregates are considered, only clean, well-graded, and washed materials with verified low fines and salt content should be used.<\/p>\n<h3>Layer thickness and tolerances<\/h3>\n<p>The installation thickness typically ranges from 3-5 cm. For large-format slabs, irregular natural stones, or dynamically loaded areas, stricter tolerances are required. Screeding is done higher than the target elevation so that vibrating in or tapping in brings the stones to the planned level. What is essential is a <strong>uniform bedding thickness<\/strong> without \u201cdishes\u201d or \u201chumps.\u201d Precompaction of the screeded bedding is not permissible; a minor, controlled settlement during vibratory compaction of the surfacing is accounted for in the screed height.<\/p>\n<h3>Flatness and slope<\/h3>\n<p>The bedding layer provides the final fine adjustment of the slope. It must precisely correspond to the planned drainage so that joints and bedding are not permanently exposed to standing water. Standing moisture must be avoided; the base course must be permeable and sufficiently load-bearing. As a guide, surface gradients of approximately 1.5-2.5 percent have proven effective depending on surface texture and exposure.<\/p>\n<h2>Execution: Step by step to a functional bedding layer<\/h2>\n<h3>Preparation and separation layers<\/h3>\n<p>A separation or filter layer (e.g., <strong>geotextile<\/strong>) can be applied to the compacted base course to prevent fines from washing into the bedding. This increases durability and ease of maintenance. The geotextile should be selected for appropriate filtration and puncture resistance, with overlaps laid in the direction of drainage and secured against wind uplift.<\/p>\n<h3>Screeding the bedding<\/h3>\n<ol>\n<li>Set screed rails to the correct elevation and slope<\/li>\n<li>Distribute bedding material evenly<\/li>\n<li>Screed off level with a screed board, neatly close rail imprints<\/li>\n<li>Do not walk on the screeded surface and protect it from the weather<\/li>\n<li>Verify bedding thickness and flatness with spot checks and a straightedge<\/li>\n<\/ol>\n<p>Installation should be carried out in sections so that laying can follow promptly. In wind and heavy rain, loosening and grain rearrangement must be avoided. In case of precipitation risk or overnight pauses, cover the screeded areas to prevent saturation or contamination.<\/p>\n<h3>Laying, tapping in, vibrating in<\/h3>\n<p>Stones are placed with tight joints into the still loose bedding chippings. Vibrating-in is performed with suitable plate size and an intermediate layer (rubber mat), adapted to format and surface. The goal is <em>uniform load transfer<\/em> without overcompaction of the bedding. Work proceeds from fixed edges toward open edges; sensitive surfaces require reduced vibration energy and edge zones are compacted with particular care to avoid rocking and edge breakage.<\/p>\n<h3>Joint filling and initial care<\/h3>\n<p>The joints are filled with suitable material (chippings, sand, or bound systems) and re-vibrated. Washouts must be monitored in the initial period and refilled if necessary. For unbound systems, use dry, clean jointing material and sweep repeatedly until joints remain topped up; for bound systems, adhere to curing and protection times to prevent early damage.<\/p>\n<h2>Bound or unbound: system selection based on use<\/h2>\n<p>Unbound bedding layers are standard in path and plaza construction because they are permeable, practical to build, and easy to maintain. For large-format slabs, high point loads, or representative areas with tight flatness tolerances, <strong>bound bedding layers<\/strong> (drainage or grouting mortar) are used. Drainage via open joints, drainage mortars, and appropriate base courses must be ensured. Transitions between bound and unbound systems must be carefully planned to control shear forces and avoid cracking. Movement joints, compatibility with de-icing agents, and moisture management beneath impermeable coverings are additional selection criteria.<\/p>\n<h2>Special aspects for natural stone paving and large-format slabs<\/h2>\n<h3>Natural stone with irregular tolerances<\/h3>\n<p>When laying natural stone with dimensional tolerances, the bedding acts as a compensation layer that accommodates each stone at the correct height. Angular chippings prevent rocking. For very irregular undersides, a slightly increased bedding thickness can be useful-without compromising permeability. If bound bedding is chosen, full-surface support is required; spot bedding produces stress peaks and should be avoided.<\/p>\n<h3>Large formats and shear-resistant support<\/h3>\n<p>Large-format slabs require particularly homogeneous support. Point loads must be avoided, for example by full-surface buttering in bound bedding or by uniform, fine-grained chippings in unbound execution. Expansion joints, edge restraints, and joint widths must be dimensioned to suit thermal and dynamic loads. Limiting thickness tolerances and ensuring full bearing under a straightedge reduces tensile stresses and the risk of cracking.<\/p>\n<h2>Quality assurance, typical defects, and prevention<\/h2>\n<h3>Frequent causes of defects<\/h3>\n<ul>\n<li>Excessive fines content: clogging, frost heave, \u201cpumping\u201d<\/li>\n<li>Non-uniform bedding thickness: settlements, rocking, edge breakage<\/li>\n<li>Missing slope or blocked drainage paths: standing water, efflorescence<\/li>\n<li>Excessive vibrating-in: grain crushing, bedding densification<\/li>\n<li>Missing or yielding edge restraints: shear displacement<\/li>\n<li>Contamination of bedding with clay or cement paste: loss of permeability<\/li>\n<li>Premature trafficking before completion: deformation and joint loss<\/li>\n<\/ul>\n<h3>Inspection and documentation<\/h3>\n<p>Flatness, layer thicknesses, and material properties must be checked. Random sieve analyses and visual inspections of the bedding before laying increase execution reliability. For bound systems, note consistency, substrate bond, and curing conditions. Flatness of the finished surface is typically verified with a straightedge and documented against the specified tolerance class; photographic and measurement logs support traceability.<\/p>\n<h2>Deconstruction, rehabilitation, and selective demolition of the bedding layer<\/h2>\n<p>In rehabilitation, damaged zones of the bedding are often replaced, joints are cleaned, and the bedding is locally supplemented. In complete deconstruction, separating the material streams (stones\/slabs, bedding, base course) is key for <strong>recycling<\/strong>. If suitable and cleanly separated, the bedding material can be reused or processed as a secondary raw material. Mixing bound and unbound residues should be avoided to preserve recycling options and material quality.<\/p>\n<h3>Low-impact removal of components<\/h3>\n<p>In dense urban areas, heritage sites, or noise-sensitive zones, edge restraints, curb stones, and concrete slabs are often removed with <em>low vibration levels<\/em> for selective dismantling. <strong>Concrete demolition shear<\/strong> breaks and downsizes concrete components in a controlled manner, exposing the bedding beneath so it can be separated with minimal contaminants. <strong>Hydraulic wedge splitter<\/strong> and <a href=\"https:\/\/www.darda.de\/en\/product-overview\/hydraulic-rock-and-concrete-splitters\">handheld rock and concrete splitters<\/a> separate massive elements such as curb stones or thick slabs without impact peaks or vibrations. This supports material-conserving deconstruction as required in <a href=\"https:\/\/www.darda.de\/en\/applications\/concrete-demolition-and-special-deconstruction\">concrete demolition and special deconstruction<\/a>. Pre-cutting and targeted splitting reduce transmission of forces into adjacent surfaces.<\/p>\n<h3>Hydraulic support in practice<\/h3>\n<p>Hydraulically powered tools are supplied by suitable <strong><a href=\"https:\/\/www.darda.de\/en\/product-overview\/hydraulic-power-units\">hydraulic power pack<\/a><\/strong> units. Their compact design enables work in confined spaces-such as during partial openings of paving for <strong>utility installation<\/strong> or repair areas. In this way, the bedding can be removed, replaced, and restored locally without causing large-scale damage. Controlled sequencing and short set-up times help limit closures and protect surrounding structures.<\/p>\n<h2>Relation to Darda GmbH application areas<\/h2>\n<p>The bedding layer itself is part of path and plaza construction; interfaces arise mainly during alteration and deconstruction:<\/p>\n<ul>\n<li><strong>Concrete demolition<\/strong> and <strong>special demolition<\/strong>: Selective opening of paved areas, removal of curb and edge restraints, downsizing concrete slabs to expose the bedding using <strong>concrete demolition shear<\/strong> or <strong>hydraulic wedge splitter<\/strong><\/li>\n<li>Gutting works and cutting: In exterior areas of existing buildings, access routes are created across paved surfaces; low-vibration cutting and splitting operations minimize impacts on the surroundings<\/li>\n<li>Natural stone extraction: When producing paving stones or slabs, targeted splitting of raw blocks plays a role; the subsequent requirements for the bedding depend on format, tolerances, and rock type<\/li>\n<li>Special applications: Work in sensitive areas, such as historic pavements, requires precise removal of individual elements and careful restoration of the bedding<\/li>\n<\/ul>\n<h2>Sustainability, drainage, and climate adaptation<\/h2>\n<p>Unbound, permeable bedding layers support infiltration and relieve drainage systems. In combination with open-pored joint materials and permeable base courses, surfaces with high rainwater retention capacity are created. During deconstruction, separate collection of bedding and paving stones enables reuse. Clean <strong>construction logistics<\/strong> are important to avoid foreign materials in the bedding. Regular maintenance-such as sweeping and vacuuming of joints-helps preserve permeability and supports climate-resilient site drainage.<\/p>\n<h2>Interfaces: edge restraints, shafts, and built-in components<\/h2>\n<p>Edge restraints secure the pavement against lateral displacement. The bedding must be constructed at edges, shafts, and built-in components to the correct elevation and with shear resistance. In upgrades, edge components are often removed first. <strong>Concrete demolition shear<\/strong> and <strong>hydraulic wedge splitter<\/strong> enable controlled removal of curb stones and edge restraints before the bedding is locally renewed or adjusted. Compaction and bedding continuity beneath and alongside edge elements are essential to prevent rotation and loss of joint integrity.<\/p>\n<h2>Occupational safety and protecting the surroundings<\/h2>\n<p>Dust, noise, and vibrations must be minimized during laying and deconstruction tasks. Permeable materials can generate dust in dry conditions; appropriate <strong>dust suppression<\/strong> measures may be required. In selective demolition, splitting, hydraulic methods reduce vibrations, protecting adjacent structures, utilities, and already installed surfaces. Ergonomic handling of heavy slabs and use of lifting aids, as well as suitable PPE, reduce strain and improve on-site safety.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The paver bedding layer is the laying course located directly beneath the paving stones or slabs. It largely determines the flatness, load-bearing capacity, and durability of a paved surface-from garden driveways to heavily trafficked areas. In new construction, repair, and deconstruction, the choice of bedding material, the correct layer thickness, <a class=\"moretag\" href=\"https:\/\/www.darda.de\/en\/knowledge\/paver-bedding-layer\">read more&#8230;<\/a><\/p>\n","protected":false},"author":9,"featured_media":0,"parent":14846,"menu_order":0,"comment_status":"open","ping_status":"open","template":"tmpl\/template-wissen.php","meta":{"_acf_changed":false,"footnotes":"","_members_access_role":[],"_members_access_error":""},"class_list":["post-19528","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Paver Bedding Layer | Laying Course Guide<\/title>\n<meta name=\"description\" content=\"Guide \u2713 to the paver bedding layer laying course - choose materials, thickness &amp; methods for stable, draining pavements.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.darda.de\/en\/knowledge\/paver-bedding-layer\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Paver Bedding Layer | Laying Course Guide\" \/>\n<meta property=\"og:description\" content=\"Guide \u2713 to the paver bedding layer laying course - choose materials, thickness &amp; methods for stable, draining pavements.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.darda.de\/en\/knowledge\/paver-bedding-layer\" \/>\n<meta property=\"og:site_name\" content=\"Darda GmbH\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/DardaDemolition\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-04T09:38:03+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/paver-bedding-layer\",\"url\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/paver-bedding-layer\",\"name\":\"Paver Bedding Layer | Laying Course Guide\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#website\"},\"datePublished\":\"2025-11-20T07:17:33+00:00\",\"dateModified\":\"2026-05-04T09:38:03+00:00\",\"description\":\"Guide \u2713 to the paver bedding layer laying course - choose materials, thickness & methods for stable, draining pavements.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/paver-bedding-layer#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/paver-bedding-layer\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/paver-bedding-layer#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.darda.de\\\/en\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Knowledge\",\"item\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Paver bedding layer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#website\",\"url\":\"https:\\\/\\\/www.darda.de\\\/en\",\"name\":\"Darda GmbH\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#organization\"},\"alternateName\":\"Abbruchwerkzeuge\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.darda.de\\\/en?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#organization\",\"name\":\"Darda GmbH\",\"url\":\"https:\\\/\\\/www.darda.de\\\/en\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.darda.de\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/android-icon-192x192-1.png\",\"contentUrl\":\"https:\\\/\\\/www.darda.de\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/android-icon-192x192-1.png\",\"width\":192,\"height\":192,\"caption\":\"Darda GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/DardaDemolition\",\"https:\\\/\\\/www.instagram.com\\\/darda_demolition\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/DardaGmbH\",\"https:\\\/\\\/www.xing.com\\\/pages\\\/darda-gmbh\",\"https:\\\/\\\/de.linkedin.com\\\/company\\\/darda-gmbh\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Paver Bedding Layer | Laying Course Guide","description":"Guide \u2713 to the paver bedding layer laying course - choose materials, thickness & methods for stable, draining pavements.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.darda.de\/en\/knowledge\/paver-bedding-layer","og_locale":"en_US","og_type":"article","og_title":"Paver Bedding Layer | Laying Course Guide","og_description":"Guide \u2713 to the paver bedding layer laying course - choose materials, thickness & methods for stable, draining pavements.","og_url":"https:\/\/www.darda.de\/en\/knowledge\/paver-bedding-layer","og_site_name":"Darda GmbH","article_publisher":"https:\/\/www.facebook.com\/DardaDemolition","article_modified_time":"2026-05-04T09:38:03+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.darda.de\/en\/knowledge\/paver-bedding-layer","url":"https:\/\/www.darda.de\/en\/knowledge\/paver-bedding-layer","name":"Paver Bedding Layer | Laying Course Guide","isPartOf":{"@id":"https:\/\/www.darda.de\/en#website"},"datePublished":"2025-11-20T07:17:33+00:00","dateModified":"2026-05-04T09:38:03+00:00","description":"Guide \u2713 to the paver bedding layer laying course - choose materials, thickness & methods for stable, draining pavements.","breadcrumb":{"@id":"https:\/\/www.darda.de\/en\/knowledge\/paver-bedding-layer#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.darda.de\/en\/knowledge\/paver-bedding-layer"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.darda.de\/en\/knowledge\/paver-bedding-layer#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.darda.de\/en"},{"@type":"ListItem","position":2,"name":"Knowledge","item":"https:\/\/www.darda.de\/en\/knowledge"},{"@type":"ListItem","position":3,"name":"Paver bedding layer"}]},{"@type":"WebSite","@id":"https:\/\/www.darda.de\/en#website","url":"https:\/\/www.darda.de\/en","name":"Darda GmbH","description":"","publisher":{"@id":"https:\/\/www.darda.de\/en#organization"},"alternateName":"Abbruchwerkzeuge","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.darda.de\/en?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.darda.de\/en#organization","name":"Darda GmbH","url":"https:\/\/www.darda.de\/en","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.darda.de\/en#\/schema\/logo\/image\/","url":"https:\/\/www.darda.de\/wp-content\/uploads\/2017\/09\/android-icon-192x192-1.png","contentUrl":"https:\/\/www.darda.de\/wp-content\/uploads\/2017\/09\/android-icon-192x192-1.png","width":192,"height":192,"caption":"Darda GmbH"},"image":{"@id":"https:\/\/www.darda.de\/en#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/DardaDemolition","https:\/\/www.instagram.com\/darda_demolition","https:\/\/www.youtube.com\/user\/DardaGmbH","https:\/\/www.xing.com\/pages\/darda-gmbh","https:\/\/de.linkedin.com\/company\/darda-gmbh"]}]}},"_links":{"self":[{"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages\/19528","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/comments?post=19528"}],"version-history":[{"count":2,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages\/19528\/revisions"}],"predecessor-version":[{"id":26880,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages\/19528\/revisions\/26880"}],"up":[{"embeddable":true,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages\/14846"}],"wp:attachment":[{"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/media?parent=19528"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}