{"id":19054,"date":"2025-10-14T09:16:33","date_gmt":"2025-10-14T07:16:33","guid":{"rendered":"https:\/\/www.darda.de\/double-layer-reinforcement"},"modified":"2026-04-01T09:09:03","modified_gmt":"2026-04-01T07:09:03","slug":"double-layer-reinforcement","status":"publish","type":"page","link":"https:\/\/www.darda.de\/en\/knowledge\/double-layer-reinforcement","title":{"rendered":"Double-layer reinforcement"},"content":{"rendered":"<div class=\"wissen-inhaltsbereich\">\n<p>Double-layer reinforcement is a central design principle of reinforced concrete construction. It is encountered by designers, contractors, and teams in concrete demolition alike: in cast-in-place slabs and walls, in floor slabs, in tunnel linings, and in highly stressed components. For deconstruction, arranging two reinforcement layers has significant consequences: cross-sections are tougher, crack patterns change, and the choice of separation and splitting methods &#8211; such as the use of concrete pulverizers or <a href=\"https:\/\/www.darda.de\/en\/product-overview\/hydraulic-rock-and-concrete-splitters\">rock and concrete splitters<\/a> with suitable hydraulic power packs &#8211; has to be aligned with it. These interrelations are particularly decisive in practice in the fields of concrete demolition and special demolition, strip-out and cutting, as well as rock excavation and tunnel construction. In reinforced concrete practice, the configuration also governs serviceability and durability, which in turn inform selective demolition strategies and tool logistics.<\/p>\n<h2>Definition: What is meant by double-layer reinforcement?<\/h2>\n<p>Double-layer reinforcement refers to two reinforcement layers in a component separated from each other, typically as a top and bottom layer (e.g., in slabs, decks, floor slabs) or as layers on both faces (e.g., in walls and shells). Between the layers there is concrete with defined cover to the outside. The layers are often positioned using spacers or lattice girders. The aim is to take bending tension forces in both edge zones, limit crack widths, ensure shear capacity and punching resistance, and reliably transfer loads from alternating directions. Double-layer reinforcement is typically executed with meshes or individual bars, supplemented by shear reinforcement and anchorage bars.<\/p>\n<ul>\n<li><strong>Orientation<\/strong>: top and bottom in slabs or both faces in walls and shells for actions from both directions<\/li>\n<li><strong>Concrete cover<\/strong>: ensures corrosion protection, fire resistance, and reliable bond<\/li>\n<li><strong>Assembly aids<\/strong>: spacers and lattice girders for positional stability during concreting and later deconstruction<\/li>\n<li><strong>Complementary steel<\/strong>: stirrups, shear rails, and anchorage bars to secure shear and punching resistance<\/li>\n<\/ul>\n<h2>Configuration and mode of action of double-layer reinforcement<\/h2>\n<p>The two layers are arranged so that they cover the tension zones of the member. In slabs, one layer lies on top (for support and fixed-end regions), the other at the bottom (for field moments). In walls, layers are arranged on both faces to handle actions from both directions. Concrete cover protects against corrosion and ensures bond. Depending on the load case, additional elements such as shear dowels, punching shear reinforcement, and stirrups are integrated. Detailing governs crack spacing, deformation, and residual capacity, which are decisive for controlled dismantling and size reduction.<\/p>\n<h3>Reinforcement layout, concrete cover, and spacing<\/h3>\n<p>The effective position of the bars depends on concrete cover, bar diameter, concrete strength, and bond. The spacing between the layers influences flexural stiffness and crack distribution: a larger internal lever arm increases load-bearing capacity but requires precise positional stability. Spacers and lattice girders secure the geometry, which is important both for construction and for later deconstruction. In practice, tolerances from construction influence the as-built lever arm and must be considered when planning cutting, splitting, and lifting sequences.<\/p>\n<h3>Mesh and bar reinforcement, bond and crack pattern<\/h3>\n<p>Mesh reinforcement accelerates installation, bar reinforcement enables targeted strengthening and lap splices. The bond between concrete and steel governs the crack pattern: with double-layer reinforcement, finer but denser cracks often occur. For deconstruction, this means a tougher material behavior that must be taken into account when cutting, splitting, and crushing. Where lap zones or anchorage regions are expected, incremental exposure and staged cutting reduce unplanned energy release and limit secondary cracking.<\/p>\n<h2>Typical use cases<\/h2>\n<p>Double-layer reinforcement is used wherever loads act from different directions, high serviceability is required, or durability is paramount. Practical examples:<\/p>\n<ul>\n<li>Floor and slab structures with large spans or high live loads<\/li>\n<li>Walls, retaining walls, shafts, and tanks with two-sided actions<\/li>\n<li>Floor slabs, especially under alternating loads and dynamic actions<\/li>\n<li>Tunnel linings and frame structures in structural\/civil engineering<\/li>\n<li>Watertight structures where crack width limitation is governing<\/li>\n<li>Bridge and deck slabs with exposure classes requiring enhanced durability<\/li>\n<\/ul>\n<h2>Implications for deconstruction, separation, and splitting methods<\/h2>\n<p>The two-layer reinforcement increases ductility and residual load-bearing capacity &#8211; an advantage for safety during deconstruction, but an additional challenge for separation technology. Depending on member thickness, reinforcement ratio, and accessibility, different approaches are suitable. In many scenarios, a combination of concrete pulverizers, rock and concrete splitters, and subsequent steel cutting (e.g., with steel shears or multi cutters) has proven effective. Hydraulic power packs provide the necessary power supply.<\/p>\n<ul>\n<li><strong>Member behavior<\/strong>: higher confinement and bridging by the second layer require sectional dismantling<\/li>\n<li><strong>Tool interaction<\/strong>: phased concrete removal followed by steel cutting reduces tool wear and unplanned fracture<\/li>\n<li><strong>Access strategy<\/strong>: interior work benefits from compact equipment and pre-sized segments<\/li>\n<\/ul>\n<h3>Concrete pulverizers in densely reinforced sections<\/h3>\n<p>Concrete pulverizers grip positively, crush the concrete, and expose the bars. With double-layer reinforcement, the second layer creates higher retention; size reduction is therefore carried out in sections, with targeted &#8220;bites&#8221; along planned fracture lines. In this way meshes and bars are exposed in a controlled manner and then cut in the next step. <em>strip-out and cutting<\/em> beforehand reduces the cross-section and makes working with the pulverizer in interior areas easier. Staged reduction also helps to avoid unintended load paths into adjacent components.<\/p>\n<h3>Rock and concrete splitters for massive cross-sections<\/h3>\n<p>Hydraulic splitting uses boreholes to introduce splitting forces without explosives. In members with double-layer reinforcement, the reinforcement can locally inhibit crack propagation. Therefore, splitting holes are positioned to guide cracks past the steel, and the splitting process is carried out in stages. With limited access &#8211; such as in <strong>special demolition<\/strong> &#8211; the splitting method enables low-vibration and controlled removal.<\/p>\n<ul>\n<li>Define drilling patterns with edge distances and spacing adapted to reinforcement layout<\/li>\n<li>Stage the splitting pressure to steer crack propagation between layers<\/li>\n<li>Use verification bores to confirm mesh direction before full deployment<\/li>\n<\/ul>\n<h3>Combination with steel shears and multi cutters<\/h3>\n<p>After exposing the steel, the reinforcement is cut. Steel shears and multi cutters cut bundles and larger diameters quickly. In dense reinforcement layouts in support and node regions, a finely tuned sequence is advantageous: first crushing with the concrete pulverizer, then splitting in remaining areas, followed by targeted cutting of the bars. Cutting should only proceed once concrete confinement is sufficiently released to minimize rebound and peripheral damage.<\/p>\n<h2>Design and detailing: relevance for construction and deconstruction<\/h2>\n<p>Design rules (e.g., in accordance with widely accepted technical standards) define reinforcement ratios, crack width limitation, and anchorage. For deconstruction, these provide important information: position of top and bottom meshes, lap lengths, punching and shear reinforcement. Where available documentation is missing, construction-phase investigation is advisable to adapt the selection of equipment &#8211; especially concrete pulverizers and rock and concrete splitters &#8211; to the actual reinforcement condition. Reading as-built tolerances and cover deviations helps calibrate splitting pressure, bite depth, and cutting sequence.<\/p>\n<h3>Pre-investigation and reinforcement locating<\/h3>\n<p>Before cutting, splitting, or pulverizing, a systematic investigation is recommended. This helps reduce risks and effort:<\/p>\n<ul>\n<li>Review drawings and identify structural hotspots (supports, punching zones)<\/li>\n<li>Reinforcement locating (e.g., magnetic induction, radar) to estimate position and diameters<\/li>\n<li>Trial exposures at edge zones for verification<\/li>\n<li>Definition of cutting and splitting lines with regard to reinforcement routing<\/li>\n<li>Matching hydraulic power packs to the anticipated resistance<\/li>\n<li>Assessment of potential prestressing and post-installed anchors in adjacent areas<\/li>\n<\/ul>\n<h2>Workflow in special demolition with double-layer reinforcement<\/h2>\n<p>A structured workflow proves itself in tight schedules and sensitive environments, such as in existing buildings or urban areas:<\/p>\n<ol>\n<li>Strip-out and cutting: removal of non-load-bearing layers, disconnection of attachments and installations<\/li>\n<li>Preparation: marking the cuts, core drilling for lifting points and splitting holes<\/li>\n<li>Primary separation: concrete pulverizers along the planned lines or splitters for low-vibration partitioning<\/li>\n<li>Secondary separation: steel shears\/multi cutters for exposed reinforcement bars<\/li>\n<li>Sizing and sorting: material separation concrete\/steel for transport and recycling<\/li>\n<\/ol>\n<p>Depending on boundary conditions, temporary supports and lifting aids are coordinated early. Sequencing favors peripheral relief cuts before core removal to maintain control over stability and emissions.<\/p>\n<h2>Safety, emissions, and environmental protection<\/h2>\n<p>With double-layer reinforcement, the mechanical demand on the tools increases. A clear work zone, coordinated load handling, and regular inspection of hydraulic connections are essential. Vibrations, noise, and dust are reduced by appropriate methods and water misting. Splitting methods generally operate with low vibration; concrete pulverizers enable controlled removal. Requirements from occupational safety and environmental law must be reviewed project-specifically and implemented accordingly.<\/p>\n<ul>\n<li><strong>Tool integrity<\/strong>: monitor jaws, hoses, and couplings for leaks and wear<\/li>\n<li><strong>Emission control<\/strong>: plan water supply, capture dust at source, and optimize bite size<\/li>\n<li><strong>Stability<\/strong>: verify temporary edge conditions before cutting dense bar bundles<\/li>\n<\/ul>\n<h2>Special considerations in tunnel construction and watertight components<\/h2>\n<p>Tunnel linings and watertight structures often have high reinforcement ratios in two layers. Accessibility is limited, boundary conditions are tight. In such cases, compact hydraulic power packs are combined with concrete pulverizers or rock and concrete splitters to release the cross-sections step by step. In the context of rock excavation and tunnel construction, experience with splitting technology from natural stone extraction can be utilized: controlled crack propagation is a key advantage, but with double-layer reinforcement it must be specifically supported by the placement of splitting holes. Interfaces to waterproofing, gaskets, and joints require particularly careful sequencing to avoid leakage paths.<\/p>\n<h2>Openings, breakthroughs, and support zones<\/h2>\n<p>For subsequent openings in slabs and walls with double-layer reinforcement, the edge areas are often provided with additional reinforcement. It is advisable to choose cutting sequences that first relieve the edge areas and then separate the core zones. Splitting holes are positioned so that cracks pass by the bars; concrete pulverizers crumble the concrete locally until the steel is accessible. In support regions and nodes, stirrups and closely spaced bars should be expected. Where ring beams or edge stiffeners exist, partial exposure and sectional cutting minimize secondary cracking around the opening.<\/p>\n<h2>Material separation and recycling<\/h2>\n<p>The two-stage approach &#8211; release the concrete, then cut the steel &#8211; leads to well-sortable fractions. This promotes the reuse of concrete debris and reinforcing steel. Concrete pulverizers produce fragment sizes suitable for handling, splitters divide massive members without major edge damage. Steel shears provide clean separation even of thick bundles. Material streams can be documented by fraction to support recycling quotas and traceability.<\/p>\n<h2>Practical guidance for selecting and using the equipment<\/h2>\n<p>Member thickness, reinforcement ratio, accessibility, and environmental requirements are decisive. Concrete pulverizers are advantageous when access is good and controlled removal is needed. Rock and concrete splitters show their strengths when vibrations must be minimized or massive cross-sections are to be divided without extensive saw cuts. Hydraulic power packs must be matched to the power demand of the respective tools. In special assignments, for example in sensitive existing structures, methods are often combined and executed section by section.<\/p>\n<ul>\n<li><strong>Access and reach<\/strong>: choose jaw geometry and cylinder force to suit confined spaces<\/li>\n<li><strong>Sectioning strategy<\/strong>: define bite size, splitting stages, and cut order in the method statement<\/li>\n<li><strong>Energy management<\/strong>: align hydraulic flow and pressure with peak tool demand to avoid downtime<\/li>\n<\/ul>\n<h2>Terminological distinction and classification in everyday construction practice<\/h2>\n<p>Double-layer reinforcement is not to be equated with doubling reinforcement in partial areas: it means two independent, structurally defined layers. In everyday construction it affects load-bearing capacity, serviceability, and durability &#8211; and in deconstruction the choice of means. Those who work with concrete pulverizers, rock and concrete splitters, steel shears, or multi cutters benefit from clear planning, careful investigation, and a step-by-step, controlled approach. Precise use of terms in documentation and work planning avoids misunderstandings on site and streamlines interfaces between engineering, site management, and equipment operations.<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Double-layer reinforcement is a central design principle of reinforced concrete construction. It is encountered by designers, contractors, and teams in concrete demolition alike: in cast-in-place slabs and walls, in floor slabs, in tunnel linings, and in highly stressed components. For deconstruction, arranging two reinforcement layers has significant consequences: cross-sections are <a class=\"moretag\" href=\"https:\/\/www.darda.de\/en\/knowledge\/double-layer-reinforcement\">read more&#8230;<\/a><\/p>\n","protected":false},"author":9,"featured_media":0,"parent":14846,"menu_order":0,"comment_status":"open","ping_status":"open","template":"tmpl\/template-wissen.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-19054","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Double-Layer Reinforcement in Reinforced Concrete<\/title>\n<meta name=\"description\" content=\"Insights on double-layer reinforcement in reinforced concrete \u2713 design, crack control &amp; safe demolition.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.darda.de\/en\/knowledge\/double-layer-reinforcement\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Double-Layer Reinforcement in Reinforced Concrete\" \/>\n<meta property=\"og:description\" content=\"Insights on double-layer reinforcement in reinforced concrete \u2713 design, crack control &amp; safe demolition.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.darda.de\/en\/knowledge\/double-layer-reinforcement\" \/>\n<meta property=\"og:site_name\" content=\"Darda GmbH\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/DardaDemolition\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-01T07:09:03+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"10 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/double-layer-reinforcement\",\"url\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/double-layer-reinforcement\",\"name\":\"Double-Layer Reinforcement in Reinforced Concrete\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#website\"},\"datePublished\":\"2025-10-14T07:16:33+00:00\",\"dateModified\":\"2026-04-01T07:09:03+00:00\",\"description\":\"Insights on double-layer reinforcement in reinforced concrete \u2713 design, crack control & safe demolition.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/double-layer-reinforcement#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/double-layer-reinforcement\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/double-layer-reinforcement#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.darda.de\\\/en\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Knowledge\",\"item\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Double-layer reinforcement\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#website\",\"url\":\"https:\\\/\\\/www.darda.de\\\/en\",\"name\":\"Darda GmbH\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#organization\"},\"alternateName\":\"Abbruchwerkzeuge\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.darda.de\\\/en?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#organization\",\"name\":\"Darda GmbH\",\"url\":\"https:\\\/\\\/www.darda.de\\\/en\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.darda.de\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/android-icon-192x192-1.png\",\"contentUrl\":\"https:\\\/\\\/www.darda.de\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/android-icon-192x192-1.png\",\"width\":192,\"height\":192,\"caption\":\"Darda GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/DardaDemolition\",\"https:\\\/\\\/www.instagram.com\\\/darda_demolition\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/DardaGmbH\",\"https:\\\/\\\/www.xing.com\\\/pages\\\/darda-gmbh\",\"https:\\\/\\\/de.linkedin.com\\\/company\\\/darda-gmbh\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Double-Layer Reinforcement in Reinforced Concrete","description":"Insights on double-layer reinforcement in reinforced concrete \u2713 design, crack control & safe demolition.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.darda.de\/en\/knowledge\/double-layer-reinforcement","og_locale":"en_US","og_type":"article","og_title":"Double-Layer Reinforcement in Reinforced Concrete","og_description":"Insights on double-layer reinforcement in reinforced concrete \u2713 design, crack control & safe demolition.","og_url":"https:\/\/www.darda.de\/en\/knowledge\/double-layer-reinforcement","og_site_name":"Darda GmbH","article_publisher":"https:\/\/www.facebook.com\/DardaDemolition","article_modified_time":"2026-04-01T07:09:03+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"10 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.darda.de\/en\/knowledge\/double-layer-reinforcement","url":"https:\/\/www.darda.de\/en\/knowledge\/double-layer-reinforcement","name":"Double-Layer Reinforcement in Reinforced Concrete","isPartOf":{"@id":"https:\/\/www.darda.de\/en#website"},"datePublished":"2025-10-14T07:16:33+00:00","dateModified":"2026-04-01T07:09:03+00:00","description":"Insights on double-layer reinforcement in reinforced concrete \u2713 design, crack control & safe demolition.","breadcrumb":{"@id":"https:\/\/www.darda.de\/en\/knowledge\/double-layer-reinforcement#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.darda.de\/en\/knowledge\/double-layer-reinforcement"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.darda.de\/en\/knowledge\/double-layer-reinforcement#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.darda.de\/en"},{"@type":"ListItem","position":2,"name":"Knowledge","item":"https:\/\/www.darda.de\/en\/knowledge"},{"@type":"ListItem","position":3,"name":"Double-layer reinforcement"}]},{"@type":"WebSite","@id":"https:\/\/www.darda.de\/en#website","url":"https:\/\/www.darda.de\/en","name":"Darda GmbH","description":"","publisher":{"@id":"https:\/\/www.darda.de\/en#organization"},"alternateName":"Abbruchwerkzeuge","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.darda.de\/en?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.darda.de\/en#organization","name":"Darda GmbH","url":"https:\/\/www.darda.de\/en","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.darda.de\/en#\/schema\/logo\/image\/","url":"https:\/\/www.darda.de\/wp-content\/uploads\/2017\/09\/android-icon-192x192-1.png","contentUrl":"https:\/\/www.darda.de\/wp-content\/uploads\/2017\/09\/android-icon-192x192-1.png","width":192,"height":192,"caption":"Darda GmbH"},"image":{"@id":"https:\/\/www.darda.de\/en#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/DardaDemolition","https:\/\/www.instagram.com\/darda_demolition","https:\/\/www.youtube.com\/user\/DardaGmbH","https:\/\/www.xing.com\/pages\/darda-gmbh","https:\/\/de.linkedin.com\/company\/darda-gmbh"]}]}},"_links":{"self":[{"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages\/19054","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/comments?post=19054"}],"version-history":[{"count":1,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages\/19054\/revisions"}],"predecessor-version":[{"id":25859,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages\/19054\/revisions\/25859"}],"up":[{"embeddable":true,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages\/14846"}],"wp:attachment":[{"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/media?parent=19054"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}