{"id":19007,"date":"2025-10-20T10:23:56","date_gmt":"2025-10-20T08:23:56","guid":{"rendered":"https:\/\/www.darda.de\/fire-protection-renovation-upgrade"},"modified":"2026-03-28T12:46:03","modified_gmt":"2026-03-28T11:46:03","slug":"fire-protection-renovation-upgrade","status":"publish","type":"page","link":"https:\/\/www.darda.de\/en\/knowledge\/fire-protection-renovation-upgrade","title":{"rendered":"Fire protection renovation\/upgrade"},"content":{"rendered":"<div class=\"wissen-inhaltsbereich\">\n<p>Fire protection renovation\/upgrade encompasses all measures required to restore or increase the safety of structures after a fire event or in the course of a fire protection upgrade. The focus is on the selective deconstruction of damaged components, the creation and upgrading of fire compartments, and the professional execution of fire stops and penetrations. In practice, precise, low-spark, and low-vibration methods play a central role &#8211; for example, the use of <strong>concrete pulverizers<\/strong> and <strong><a href=\"https:\/\/www.darda.de\/en\/product-overview\/hydraulic-rock-and-concrete-splitters\">stone and concrete splitters<\/a><\/strong> powered by <a href=\"https:\/\/www.darda.de\/en\/product-overview\/hydraulic-power-units\">hydraulic power packs<\/a>. These hydraulic techniques enable targeted intervention in confined spaces with controlled debris management and minimized secondary damage.<\/p>\n<h2>Definition: What is meant by fire protection renovation\/upgrade?<\/h2>\n<p>Fire protection renovation\/upgrade refers to the technical and planning repair and upgrading of buildings and facilities with the aim of restoring the required fire resistance, the functionality of fire and smoke compartments, and the protection of load-bearing structures and escape routes. This includes the targeted deconstruction of fire-damaged construction materials, the repair or renewal of fire-protection-relevant components (e.g., walls, ceilings, service shafts), the professionally created openings and their fire stopping, as well as the documentation of the achieved protection objectives in accordance with recognized rules of practice and the applicable codes and standards.<\/p>\n<ul>\n<li><strong>Restoration of fire resistance<\/strong>: rebuilding fire and smoke compartmentation, including joints and closures.<\/li>\n<li><strong>Structural integrity<\/strong>: safeguarding and, if required, strengthening load-bearing members.<\/li>\n<li><strong>Functional safety<\/strong>: ensuring operability of escape and rescue routes and technical fire protection systems.<\/li>\n<li><strong>Evidence and traceability<\/strong>: test records, photo documentation, labeling, and maintenance information.<\/li>\n<\/ul>\n<h2>Goals, tasks, and interfaces of fire protection renovation\/upgrade<\/h2>\n<p>The renovation pursues several goals: preventing the spread of fire and smoke, preserving or restoring load-bearing capacity, securing escape and rescue routes, and ensuring technical fire protection. It lies at the interface of structural preservation, special deconstruction, and fit-out trades. <em>Selective material removal<\/em> is essential to remove only what is actually impaired. Tools such as <strong>concrete pulverizers<\/strong> and <strong>stone and concrete splitters<\/strong> support precise exposure and preparation for subsequent sealing, reprofiling, or coating &#8211; low-spark, controlled, and with low vibration.<\/p>\n<ul>\n<li><strong>Interfaces<\/strong>: structural engineering, building physics, building services, coating and lining trades, and testing laboratories.<\/li>\n<li><strong>Coordination<\/strong>: alignment with authorities, insurers, and building operation to maintain safety and minimize downtime.<\/li>\n<li><strong>Logistics<\/strong>: dust and smoke containment, phased material flows, and waste segregation.<\/li>\n<\/ul>\n<h2>Typical damage patterns after a fire and their practical implications<\/h2>\n<p>Fire exposure alters materials and details. This results in deconstruction and repair tasks:<\/p>\n<ul>\n<li>Concrete spalling due to thermal gradients; impaired concrete cover and exposed reinforcement.<\/li>\n<li>Reduced load-bearing capacity due to microstructural damage of the concrete and loss of steel strength at high temperatures.<\/li>\n<li>Weakened mortar joints in masonry, efflorescence, and smoke condensates in pore spaces.<\/li>\n<li>Damaged or weakened fire protection linings and coatings, invalidated joints and sealants.<\/li>\n<li>Service penetration fire stops (cable and pipe penetrations) compromised by the fire event, as well as dissolved compartmentation.<\/li>\n<li>Contaminated surfaces (soot, PAHs) that must be completely removed or cleaned before reprofiling and coating.<\/li>\n<li>Gypsum-based materials dehydrated by heat with reduced strength and altered fire performance.<\/li>\n<li>Moisture ingress from firefighting water leading to corrosion, biological growth, and deterioration of anchors and post-installed fasteners.<\/li>\n<\/ul>\n<p>Damage assessment combines visual inspection with measurements and testing, for example cover depth and carbonation checks, pull-off tests for substrate adhesion, non-destructive testing where suitable, and selective core sampling. The findings determine the scope and methodology of selective deconstruction and repair.<\/p>\n<h2>Selective deconstruction and preparation: overview of methods<\/h2>\n<p>Method selection is guided by accessibility, substrate condition, emission limits, and protection goals. Preference is given to controlled, low-spark, and low-vibration techniques that preserve intact adjacent components and maintain compartmentation during construction.<\/p>\n<h3>Concrete pulverizers for controlled removal<\/h3>\n<p><strong>Concrete pulverizers<\/strong> allow step-by-step crushing of concrete with high edge control. They are suitable for removing thermally damaged edge zones, exposing reinforcement, and opening local areas in slabs, walls, or columns. Advantages include minimal spark generation, low dust emissions when supplemented with extraction, and the ability to work close to existing elements without undermining them. Prepared edges improve bonding for reprofiling mortars and facilitate defined corrosion protection of reinforcement.<\/p>\n<h3>Stone and concrete splitters for low-spark, low-vibration deconstruction<\/h3>\n<p><strong>Stone and concrete splitters<\/strong> release controlled splitting forces in boreholes and create defined cracks. This method is particularly suitable when vibrations must be minimized, noise reduced, and fire loads not increased by sparks. The targeted fracture path facilitates the removal of damaged segments, for example when renewing fire-protection-relevant wall or ceiling areas. The technique supports clean interfaces for subsequent sealing and reinstatement.<\/p>\n<h3>Combination shears, multi cutters, and steel shears<\/h3>\n<p>Combination shears and multi cutters support the separation of mixed components and interior strip-out. <em>Steel shears<\/em> are helpful for safely shortening reinforcement or metallic inserts during exposure. This function-oriented separation is essential for subsequently applying coatings, linings, or fire stops professionally.<\/p>\n<h3>Tank cutters and special operations<\/h3>\n<p>In industrial environments, fire protection renovation\/upgrade may include the safe dismantling of vessels or pipelines. <em>Tank cutters<\/em> are used where controlled, preferably low-spark cutting is required and accompanying measures to minimize hazards have been implemented. This includes purging, gas measurements, inerting where necessary, and continuous atmospheric monitoring.<\/p>\n<h3>Hydraulic power packs as the energy source<\/h3>\n<p>Hydraulic power packs provide the energy for the tools mentioned. They enable mobile, finely controllable performance &#8211; an advantage when working in sensitive areas with limited power connections or strict emission requirements. Depending on the site, electrically driven units support low-noise, low-exhaust operation, while additional filtration and soundproofing further reduce emissions at the source.<\/p>\n<h2>Application areas in the context of fire protection renovation\/upgrade<\/h2>\n<ul>\n<li><strong>Concrete demolition and special demolition<\/strong>: Selective removal of fire-damaged concrete areas with <strong>concrete pulverizers<\/strong> and <strong>stone and concrete splitters<\/strong> to upgrade the load-bearing structure.<\/li>\n<li><strong>Strip-out and cutting<\/strong>: Deconstruction of linings, suspended ceilings, shafts; creating openings for new fire stops and fire doors.<\/li>\n<li><strong>Rock excavation and tunnel construction<\/strong>: After fires in tunnel structures, low-spark, low-vibration methods are in high demand; splitting technology reduces risks and vibrations.<\/li>\n<li><strong>Natural stone extraction<\/strong>: Relevant at the margins, e.g., when supplementing or replacing natural stone elements in heritage structures.<\/li>\n<li><strong>Special operations<\/strong>: Work in critical areas with potentially explosive atmospheres, sensitive facilities, or ongoing operations requires low-emission, precise methods.<\/li>\n<li><strong>Building services and plant rooms<\/strong>: Preparatory works and reinstatement around cable routes, ducts, and pipework while maintaining compartmentation.<\/li>\n<\/ul>\n<h2>Openings and fire stops: professionally creating penetrations<\/h2>\n<ol>\n<li>Planning and approval: define location, size, and fire resistance requirements; coordinate service routing and types of fire stop systems.<\/li>\n<li>Locating and condition assessment: detect services, reinforcement, and cavities; consider structural stability aspects.<\/li>\n<li>Preparation: set out drilling patterns; establish dust extraction and temporary containment; implement fire protection measures for the construction phase.<\/li>\n<li>Creating the opening: use <strong>stone and concrete splitters<\/strong> to break out the opening area with minimal cracking; cleanly trim edges with <strong>concrete pulverizers<\/strong>.<\/li>\n<li>Cleaning and substrate preparation: remove soot, loose materials, and contaminated layers; ensure adequate pull-off adhesion.<\/li>\n<li>Installation and documentation: install fire stop systems in accordance with the manufacturer\u2019s instructions and recognized rules of practice; photo documentation and labeling.<\/li>\n<li>Acceptance and maintenance: record system data and approvals, mark penetrations, and define inspection intervals for ongoing compliance.<\/li>\n<\/ol>\n<h2>Material and structural aspects<\/h2>\n<h3>Concrete<\/h3>\n<p>After thermal exposure, spalling, reduced compressive strength, and exposed reinforcement are common. Local deconstruction with <strong>concrete pulverizers<\/strong> creates defined edges for reprofiling and corrosion protection. Splitting technology facilitates the removal of larger but carefully limited areas. Where necessary, verification includes strength class checks, carbonation depth, and chloride content to inform repair design.<\/p>\n<h3>Masonry<\/h3>\n<p>Leached joints and smoke condensates require selective removal. Splitting technology can be a gentle alternative to percussive methods in highly affected areas. Repointing and local replacement units should be detailed to reinstate compartmentation and load transfer.<\/p>\n<h3>Steel and composite<\/h3>\n<p>Heated steel loses strength; linings and coatings must be renewed. <em>Steel shears<\/em> enable the separating exposure of profiles without thermal cutting, which reduces the fire load during the work. Subsequent protection may include passive fire protection systems verified for the intended exposure duration.<\/p>\n<h3>Gypsum-based and calcium silicate materials<\/h3>\n<p>Dehydration and loss of chemically bound water impair fire performance. Affected boards and panels require removal beyond visibly damaged zones to sound material. Reinstatement must ensure continuous sealing of joints and interfaces to adjacent components.<\/p>\n<h2>Emission, noise, and vibration management<\/h2>\n<ul>\n<li>Dust minimization through extraction and targeted material separation; use water mist only where safe and permitted.<\/li>\n<li>Low-vibration working methods by means of splitting technology and <strong>concrete pulverizers<\/strong>; protection of sensitive existing components and installations.<\/li>\n<li>Noise reduction through hydraulic instead of percussive methods; observe quiet periods and logistics.<\/li>\n<li>Monitoring and limits: define project-specific dust, noise, and vibration thresholds; deploy real-time measurement where necessary with documentation.<\/li>\n<li>Decontamination workflow: establish clean and dirty zones, package contaminated debris securely, and avoid cross-contamination of areas in use.<\/li>\n<\/ul>\n<h2>Occupational safety and fire protection during the renovation\/upgrade<\/h2>\n<ul>\n<li>Risk assessment and coordination of trades; permits for work, especially in potentially ignitable atmospheres.<\/li>\n<li>Prefer low-spark methods; take additional precautions when hot work is required.<\/li>\n<li>Separate work and escape routes; set up temporary smoke and dust containment.<\/li>\n<li>Continuously monitor load transfer and stability; provide temporary shoring.<\/li>\n<li>Contaminant management: define PPE for soot and PAHs, implement hygiene plans, and ensure safe waste handling.<\/li>\n<li>Tool-specific training and exclusion zones: ensure qualified operation, machine guarding, and clear signage.<\/li>\n<\/ul>\n<h2>Scheduling, quality assurance, and documentation<\/h2>\n<ol>\n<li>Survey and assessment of damage patterns; definition of renovation objectives.<\/li>\n<li>Method selection: reconcile protection goals, building condition, and operations; select suitable hydraulic tools.<\/li>\n<li>Trial areas and mock-ups: verify results, adjust boundary conditions.<\/li>\n<li>Execution with accompanying control: dimensional accuracy of openings, edge quality, substrate cleanliness.<\/li>\n<li>Completion: labeling, photo documentation, records of materials and methods used.<\/li>\n<li>Acceptance and compliance checks: compile as-built documentation, declarations of performance, and maintenance guidance for sustained conformity.<\/li>\n<\/ol>\n<h2>Sustainability and resource efficiency<\/h2>\n<p>Selective methods save material and energy because only zones that are actually impaired are removed. <strong>Stone and concrete splitters<\/strong> and <strong>concrete pulverizers<\/strong> make it possible to separate components into recoverable fractions and feed secondary raw materials back into use. Short cycle times, precise removal, and minimal secondary damage reduce the overall effort of fire protection renovation\/upgrade.<\/p>\n<ul>\n<li><strong>Material circularity<\/strong>: clean separation enables recycling and reuse where quality allows.<\/li>\n<li><strong>Reduced transport<\/strong>: localized interventions and on-site segregation shorten logistics chains.<\/li>\n<li><strong>Lifecycle perspective<\/strong>: durable reinstatement with verifiable performance extends service life and lowers future intervention needs.<\/li>\n<\/ul>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Fire protection renovation\/upgrade encompasses all measures required to restore or increase the safety of structures after a fire event or in the course of a fire protection upgrade. The focus is on the selective deconstruction of damaged components, the creation and upgrading of fire compartments, and the professional execution of <a class=\"moretag\" href=\"https:\/\/www.darda.de\/en\/knowledge\/fire-protection-renovation-upgrade\">read more&#8230;<\/a><\/p>\n","protected":false},"author":9,"featured_media":0,"parent":14846,"menu_order":0,"comment_status":"open","ping_status":"open","template":"tmpl\/template-wissen.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-19007","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Fire Protection Renovation &amp; Upgrade for Buildings<\/title>\n<meta name=\"description\" content=\"Guide to fire protection renovation and upgrade in buildings post-fire \u2713 restore compartments, structure &amp; penetrations.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.darda.de\/en\/knowledge\/fire-protection-renovation-upgrade\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fire Protection Renovation &amp; Upgrade for Buildings\" \/>\n<meta property=\"og:description\" content=\"Guide to fire protection renovation and upgrade in buildings post-fire \u2713 restore compartments, structure &amp; penetrations.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.darda.de\/en\/knowledge\/fire-protection-renovation-upgrade\" \/>\n<meta property=\"og:site_name\" content=\"Darda GmbH\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/DardaDemolition\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-28T11:46:03+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/fire-protection-renovation-upgrade\",\"url\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/fire-protection-renovation-upgrade\",\"name\":\"Fire Protection Renovation & Upgrade for Buildings\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#website\"},\"datePublished\":\"2025-10-20T08:23:56+00:00\",\"dateModified\":\"2026-03-28T11:46:03+00:00\",\"description\":\"Guide to fire protection renovation and upgrade in buildings post-fire \u2713 restore compartments, structure & penetrations.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/fire-protection-renovation-upgrade#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/fire-protection-renovation-upgrade\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\\\/fire-protection-renovation-upgrade#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.darda.de\\\/en\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Knowledge\",\"item\":\"https:\\\/\\\/www.darda.de\\\/en\\\/knowledge\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Fire protection renovation\\\/upgrade\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#website\",\"url\":\"https:\\\/\\\/www.darda.de\\\/en\",\"name\":\"Darda GmbH\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#organization\"},\"alternateName\":\"Abbruchwerkzeuge\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.darda.de\\\/en?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#organization\",\"name\":\"Darda GmbH\",\"url\":\"https:\\\/\\\/www.darda.de\\\/en\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.darda.de\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/android-icon-192x192-1.png\",\"contentUrl\":\"https:\\\/\\\/www.darda.de\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/android-icon-192x192-1.png\",\"width\":192,\"height\":192,\"caption\":\"Darda GmbH\"},\"image\":{\"@id\":\"https:\\\/\\\/www.darda.de\\\/en#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/DardaDemolition\",\"https:\\\/\\\/www.instagram.com\\\/darda_demolition\",\"https:\\\/\\\/www.youtube.com\\\/user\\\/DardaGmbH\",\"https:\\\/\\\/www.xing.com\\\/pages\\\/darda-gmbh\",\"https:\\\/\\\/de.linkedin.com\\\/company\\\/darda-gmbh\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Fire Protection Renovation & Upgrade for Buildings","description":"Guide to fire protection renovation and upgrade in buildings post-fire \u2713 restore compartments, structure & penetrations.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.darda.de\/en\/knowledge\/fire-protection-renovation-upgrade","og_locale":"en_US","og_type":"article","og_title":"Fire Protection Renovation & Upgrade for Buildings","og_description":"Guide to fire protection renovation and upgrade in buildings post-fire \u2713 restore compartments, structure & penetrations.","og_url":"https:\/\/www.darda.de\/en\/knowledge\/fire-protection-renovation-upgrade","og_site_name":"Darda GmbH","article_publisher":"https:\/\/www.facebook.com\/DardaDemolition","article_modified_time":"2026-03-28T11:46:03+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.darda.de\/en\/knowledge\/fire-protection-renovation-upgrade","url":"https:\/\/www.darda.de\/en\/knowledge\/fire-protection-renovation-upgrade","name":"Fire Protection Renovation & Upgrade for Buildings","isPartOf":{"@id":"https:\/\/www.darda.de\/en#website"},"datePublished":"2025-10-20T08:23:56+00:00","dateModified":"2026-03-28T11:46:03+00:00","description":"Guide to fire protection renovation and upgrade in buildings post-fire \u2713 restore compartments, structure & penetrations.","breadcrumb":{"@id":"https:\/\/www.darda.de\/en\/knowledge\/fire-protection-renovation-upgrade#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.darda.de\/en\/knowledge\/fire-protection-renovation-upgrade"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.darda.de\/en\/knowledge\/fire-protection-renovation-upgrade#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.darda.de\/en"},{"@type":"ListItem","position":2,"name":"Knowledge","item":"https:\/\/www.darda.de\/en\/knowledge"},{"@type":"ListItem","position":3,"name":"Fire protection renovation\/upgrade"}]},{"@type":"WebSite","@id":"https:\/\/www.darda.de\/en#website","url":"https:\/\/www.darda.de\/en","name":"Darda GmbH","description":"","publisher":{"@id":"https:\/\/www.darda.de\/en#organization"},"alternateName":"Abbruchwerkzeuge","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.darda.de\/en?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.darda.de\/en#organization","name":"Darda GmbH","url":"https:\/\/www.darda.de\/en","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.darda.de\/en#\/schema\/logo\/image\/","url":"https:\/\/www.darda.de\/wp-content\/uploads\/2017\/09\/android-icon-192x192-1.png","contentUrl":"https:\/\/www.darda.de\/wp-content\/uploads\/2017\/09\/android-icon-192x192-1.png","width":192,"height":192,"caption":"Darda GmbH"},"image":{"@id":"https:\/\/www.darda.de\/en#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/DardaDemolition","https:\/\/www.instagram.com\/darda_demolition","https:\/\/www.youtube.com\/user\/DardaGmbH","https:\/\/www.xing.com\/pages\/darda-gmbh","https:\/\/de.linkedin.com\/company\/darda-gmbh"]}]}},"_links":{"self":[{"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages\/19007","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/users\/9"}],"replies":[{"embeddable":true,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/comments?post=19007"}],"version-history":[{"count":1,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages\/19007\/revisions"}],"predecessor-version":[{"id":25767,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages\/19007\/revisions\/25767"}],"up":[{"embeddable":true,"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/pages\/14846"}],"wp:attachment":[{"href":"https:\/\/www.darda.de\/en\/wp-json\/wp\/v2\/media?parent=19007"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}